In modern foundation engineering and mineral processing, slurry purification is the core factor that determines project success. Traditional settling ponds occupy massive jobsite space and exhibit extremely low fine-sand removal rates, directly causing accelerated drill bit wear and borehole collapse. A modern industrial desanding plant completely reconstructs solid-liquid separation efficiency by organically integrating vibrating screens, hydrocyclones, and slurry pumps. As a senior field engineer, this article provides an in-depth analysis of core technical parameters, system configuration logic, and real-world jobsite performance.
Desanding Plant Core Technical Parameters and Configuration Logic
| Model | YG-100A | YG-160B | YG-200B | YG-250A | YG-250B | YG-250C | YG-300C |
| Maximum Slurry Handling Capacity | 100m³/h | 160m³/h | 200m³/h | 250m³/h | 250m³/h | 250m³/h | 300m³/h |
| Total Power | 0.5 kw | 17.2 kw | 24.2 kw | 3 kw | 25 kw | 48 kw | 59.4 kw |
| Vibratory Motor | 0.25kw×2 | 1.1kw×2 | 1.1kw×2 | 1.5kw×2 | 1.5kw×2 | 1.5kw×2 | 2.2kw×2 |
| Total Machine Weight | 550kg | 1950kg | 2050kg | 1350kg | 2300kg | 4000kg | 5500kg |
| Maximum Moisture Content in Discharged Material | 30% | 30% | 30% | 30% | 30% | 30% | 30% |
| Sand Content of Slurry After Purification | <2% | <2% | <2% | <2% | <2% | <2% | <2% |
| Separation Particle Size d50 (μm) | 180 | 180 | 180 | 180 | 180 | 180 | 180 |
| Overall Dimensions (L×W×H) | 2.5*0 .83*2 .1m | 2.7*1 .9*2 .6m | 2.7*1 .9*2 .6m | 3.7*1 .2*2 .4m | 3.3*2 .0*2 .3m | 4.0*2 .3*2 .7m | 4*3*3 .1m |
| Solids Screening Capacity (t/h) | 10-25 | 16-40 | 20-50 | 25-62.5 | 25-62.5 | 25-62.5 | 30-75 |
An efficient desanding system is never a random assembly of components. Its separation efficiency depends on feed pressure, hydrocyclone diameter, and particle classification metrics. YG Machinery’s desanding plant strictly follows mechanical engineering design principles with the following core parameter setup:
- Separation Cut Point: The primary separation index targets the -0.045mm size fraction, achieving a separation cut point d₅₀ of 180 μm, effectively removing fine sand and impurities.
- Capacity Range: Rated slurry processing capacity ranges from 100m³/h to 400m³/h, accommodating projects of various scales.
- Wear-Resistant Configuration: Hydrocyclones feature standard 3cm thick polyurethane wear-resistant liners, paired with high-chromium alloy slurry pumps, increasing high-velocity erosion resistance by over 3 times.
As a systematic solution, it provides stronger package processing and continuous operation capabilities compared to a general slurry separator machine.
Engineering Tip: During commissioning, use the flow control distribution valve to stabilize the hydrocyclone feed pressure between 0.2–0.4 MPa. Excessively high or low pressure directly degrades particle classification performance.
Operational Differences Between Single-Loop and Internal Circulation Systems


The most common jobsite challenge is fluid viscosity fluctuation. Understanding different circulation mechanisms is the key to preventing system clogging.
- Single-Loop System (A-Type): Relies on an external feed pump to inject slurry directly into the hydrocyclone. Heavier sand particles drop through the apex nozzle onto the double-deck vibrating screen for dewatering, while lightweight mud overflows. This mode features simple construction, making it ideal for coarse sand slurry without large stones.
- Internal Circulation System (B/C-Type): Equipped with a heavy-duty internal circulation slurry pump and a middle storage tank. When the slurry tank level fluctuates, a float valve automatically adjusts the replenishment pipe to achieve closed-loop pressure stabilization and secondary classification.
By scientifically selecting a mud recycling system, contractors can achieve 100% recycling of bentonite mud, substantially reducing fresh slurry procurement costs.
Engineering Tip: Running the slurry pump dry without liquid is strictly prohibited. Before startup, ensure the liquid level in the slurry tank is flush with the pump top to prevent burning out the packing seal and shaft sleeve.
Slurry Separator Multi-Industry Jobsite Applications and Technical Adaptability


Different geological conditions impose distinct challenges on desanding systems.
- Rotary and Impact Drilling: Formations frequently feature pebbles and high-viscosity clay. Systems must utilize double-deck stainless steel slot screen panels, leveraging high-frequency linear vibration to rapidly dewater solid cuttings.
- Microtunneling and Water Well Drilling: Space is limited, and the slurry sand content must be strictly reduced below 2%. Compact skid-mounted desanding stations perfectly match narrow urban jobsites.
- Mining Quarry Slurry Treatment: Processing volume is massive with severe abrasion. High-chromium alloy impellers and wear-resistant pipelines must be installed to withstand long-term quartz sand erosion.
Engineering Tip: When shutting down operations during freezing northern winters, drain accumulated water from the pump casing to prevent cracking accidents.
Overseas Customer Technical Retrofit and Success Stories

In actual overseas engineering, equipment performance speaks louder than paper specifications. Taking our YG-200B desanding plant (total power 24.2kW, weight 2,050kg) delivered to a large infrastructure project in Manila, Philippines in 2025 as an example:
The project previously utilized traditional settling ponds, where slurry sand content lingered above 8%, causing frequent wear on rotary drilling rig main pumps. After introducing YG Machinery’s system, the machine demonstrated a maximum slurry handling capacity of 200m³/h and a solids screening capacity of 20-50t/h. With a separation cut point controlled at d₅₀ of 180 μm, the sand content of the purified slurry dropped steadily to <2%, while the maximum moisture content in discharged material was held below 30%. Site maintenance personnel reported that adopting steel internal circulation piping and high-chromium alloy pumps doubled the routine maintenance interval, completely eliminating hose aging and slurry leakage issues.
Engineering Tip: Periodically inspect the foundation bolts of the vibratory motors (the YG-200B features dual 1.1kW vibratory motors). During the initial 100-hour running-in period, connection bolts must be checked and tightened every single shift.
Desanding Plant Frequently Asked Technical and Maintenance Q&A
This is usually caused by an apex nozzle blockage or low feed pressure. Stop the pump immediately to inspect whether objects larger than 2mm exist in the slurry tank, or clear the apex nozzle.
Check whether the rotation directions of the two vibrating motors are opposite, or verify if the eccentric block angles at both ends are adjusted uniformly. Ensure dual motors run synchronously in reverse directions.
The upper fine screen panel may be damaged or blinded. Remove the screen panel to inspect the back ribs for cracks, and replace with a new panel if necessary.
Engineering Tip: When servicing the slurry pump, using open flames to roast the impeller threads is strictly forbidden. Professional leverage tools must be utilized for disassembly to prevent cracking high-hardness alloys.
Conclusion and Technical Consultation
Selecting the right desanding plant is the core safeguard ensuring high-efficiency progress in deep foundation and mining engineering. To obtain detailed technical specifications, CAD drawings, or jobsite matching solutions, welcome to contact YG Machinery’s engineering technical team at any time.